US  Patent  7,138,061

SINGLE StEP LARGE COLUMNS

Liquid Loading Directly
       on Column

Dry Load up to:
      100g for the 110g or 240g
      40g for the 160g or 300g

High Resolution Packing

Direct Replacement for
       Glass Columns

Bands can be seen by Color
      or UV on the Column

Works on Biotage®*, Isco®*
       and SINGLE StEP™ Pumps

Available in many choices of
       Normal and Reversed
       Phase Sorbents

SINGLE StEP™ Large Scale Columns range from 110g-300g. SINGLE StEP™ Columns 110g-300g are rated to 100 PSI.


Biotage®Machines
SINGLE StEP™Pump
ISCO®16 Channel

Instructions for SINGLE StEP Column Loading

Best Method for Liquid Loading:
1. Don't Equilibrate your SINGLE StEP™ Columns .
2. Add compound (using glass pipette, etc.), spreading it as evenly as
possible on the top frit.
3. Screw down the cap tightly and apply air pressure from a disposable
plastic syringe (60mL) until compound is fully loaded onto the silica
beneath the frit.
4. Run 2-3 column volumes of your most non-polar solvent (1g of
silica=2mL) . This allows for polar solvents to be pushed out of the
column, and your compound to start with as low polarity as possible.
6. Replace the SINGLE StEP™ Column on the SINGLE StEP™ Pump, or Biotage®
and Isco® machines, and start running.

Best Method for Dry Loading:
1. Don't Equilibrate your SINGLE StEP™ Columns .
4. Add compound by pouring the silica or powder onto the frit.
5. Place a Head Space Frit on top of the powder and then press it down
(to make a frit "sandwich").
6. Place the column on the SINGLE StEP™ Pump, or Biotage® and Isco®
machines, and start running.

Isco® Machine Users please note:
You must place SINGLE StEP™ Columns in the "Face Forward" position in
order for them to fit on your machine.  

Ordering Information

 E.Merck® Silica Columns
Column-Merck Silica
Qty.
Compound Loading Flow Rate
4913102 SINGLE StEP 4g 20/case 50mg-200mg 6mL/min-20mL/min
4913109 SINGLE StEP 12g 20/case 300mg-600mg 6mL/min-20mL/min
4913114 SINGLE StEP 25g 20/case 700mg-1.4g 15mL/min-35mL/min
4913119 SINGLE StEP 40g 20/case 1.5g-2.5g 15mL/min-40mL/min
4913122 SINGLE StEP 80g 20/case 2.6g-4.1g 17mL/min-50mL/min
4913124 SINGLE StEP 90g 20/case 4.2g-5.6g 17mL/min-50mL/min
4913126 SINGLE StEP 110g 16/case 5.8g-6.5g 24mL/min-50mL/min
4913128 SINGLE StEP 160g 12/case 7.2g-8.4g 28mL/min-50mL/min
4913130 SINGLE StEP 240g 10/case 11.5g-13.8g 50mL/min-85mL/min
4913134 SINGLE StEP 300g 8/case 14.4g-17.0g 50mL/min-85mL/min

Standard Silica Columns
Column
Qty.
Compound Loading Flow Rate
574200 SINGLE StEP 4g 20/case 50mg-150mg 6mL/min-20mL/min
574204 SINGLE StEP 12g 20/case 200mg-500mg 6mL/min-20mL/min
574208 SINGLE StEP 40g 20/case 1.3g-2.0g 15mL/min-40mL/min
574212 SINGLE StEP 80g 20/case 2.3g-3.9g 17mL/min-50mL/min
574216 SINGLE StEP 90g 20/case 4.1g-5.2g 17mL/min-50mL/min
574218 SINGLE StEP 110g 16/case 5.8g-6.5g 24mL/min-50mL/min
574220 SINGLE StEP 160g 12/case 7.2g-8.4g 28mL/min-50mL/min
574222 SINGLE StEP 240g 10/case 11.5g-13.8g 50mL/min-85mL/min
574224 SINGLE StEP 300g 8/case 14.4g-17.0g 50mL/min-85mL/min

Head Space Frits
Sizes for each column
491250 Head Space Frits for 4g 100/case
491252 Head Space Frits for 12g 100/case
491253 Head Space Frits for 25g 100/case
491254 Head Space Frits for 40g 100/case
491256 Head Space Frits for 80g or 90g 100/case
491258 Head Space Frits: 110g or 160g 100/case
491260 Head Space Frits: 240g or 300g 100/case