N-EVAP
Analytical Nitrogen Evaporators for Sample Concentration
![]() N-EVAP Catalog No. 11250-RT |
![]() N-EVAP Catalog No. 11250-G |
![]() N-EVAP Catalog No. 11155-RT |
|
| No. of Samples | 12 | 24 | 36 |
| Instr. Cat. No. | 11155 | 11250 | 11550 |
| Bench space (w x d x h) |
13x11x31 in (33x30x80 cm) |
16x15x33
in (40x38x84 cm) |
23x22x33 in (58x56x84 cm) |
| Test tube size range | 5 to 29 mm | 10 to 29 mm | 10 to 29 mm |
| Gas flow meter range | O to 5 lpm | O to 10 lpm | O to 15 lpm |
| Inside Dia. (I.D. x depth) |
8.5x4.5 in (21.6x11.4 cm) |
12x4.5 in (30.5x11.4 cm) |
18x4.5 in (45.7x11.4 cm) |
| Outside Dim. (O.D. x height) |
13x11x7 in (33x28x18 cm) |
18x16x7 in (46x41x18cm) |
23x21x7 in (58x53x18 cm) |
| Total watts | 500 W | 800 W | 1200W |
| Voltage | 120 or 240 V | ||
| Hertz | 50 or 60 Hz | ||
| Water bath temperature range | 30° to 70° C | ||
| Accuracy | ±2°C | ||
| Dry bath temperature range |
30° to 130° C | ||
| Accuracy | ±5°C | ||
| The instrument consists of a base and stand assembly, sample holder and gas distribution system. Test tubes are held in place by a spring-loaded sample holder and support tray. Each position is numbered. The gas at 5 to 10 psig passes through an adjustable flow meter to the distribution manifold. Flexible tubing leads to valve-tube assemblies at each position. Depending on the test-tube size and solvent volume they can be individually raised or lowered to the correct height. Needles or glass pipets blow gas onto the surface of the solution resulting in rapid evaporation of the solvent. All materials used are laboratory quality and can withstand contact with organic solvents.Acid resistant models are available for corrosive applications. |
| The round, stainless steel water bath is thermostatically controlled and will accurately maintain water temperature from 30° to 70° C. Optional dry baths filled with glass or aluminum beads will operate from 30° to 130° C. A high temperature limit switch is installed for safety. An electrical GFCI plug is optional. An intrinsically safe, purged case is also available as an option. The bath is UV/CUL approved for laboratory use. |
| Options: | Suffix: |
| · Pasteur pipet fittings replace Luer fittings & needles | (-P) |
| · Acid resistant coating for corrosive environments | (-R) |
| · Dry baths with glass or aluminum beads for water-free applications or high temperatures to 130° C | (-G, -A) |
| · Phthalate free tubing replaces silicone tubing | (-H) |
| · Intrinsically safe, purged bath case | (-Z) |
| · 240 volt electrical wiring and plug | (-2) |
Please add the appropriate suffix to the catalog number when ordering